Step | Action | Value(s) | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Were you sent here from the Cooling Insufficient, A/C System diagnostic table? | -- | ||||||||||||||||
2 |
Is the liquid line cold before the orifice? | -- | ||||||||||||||||
3 | Feel along the surfaces of the following high side components for a sudden drop in temperature (The high side components should feel warm/hot from the compressor all the way to the orifice.)
Is there an abrupt drop in temperature noted along the surfaces of any of the components listed? | -- | ||||||||||||||||
4 | Feel the liquid line at the orifice location for extreme cold, possibly accompanied by heavy frost, then feel along the liquid line after the orifice location for warm temperature. Is the liquid line extremely cold at the orifice location and warm after the orifice location? | -- | ||||||||||||||||
5 | Feel along the surfaces of the following low side components for a sudden change in temperature.
Is there an abrupt temperature change felt along the surfaces of any of the components listed? | -- | ||||||||||||||||
6 | Feel along the surfaces of the following Low and High side components to compare the overall temperatures of the low and high sides.
Are the overall temperatures of the low and high side components close to the same (both only mildly warm) ? | -- | ||||||||||||||||
7 |
Is the repair complete? | -- | -- | |||||||||||||||
8 |
Is the weight of the removed refrigerant charge equal to or above the specified value? | 0.57 kg (1.25 lb) | ||||||||||||||||
9 | Recharge the A/C system to specifications. Refer to Refrigerant Recovery and Recharging . Does the cooling performance improve? | -- | ||||||||||||||||
10 |
Is the repair complete? | -- | -- | |||||||||||||||
11 |
Is the repair complete? | -- | -- | |||||||||||||||
12 |
Is there debris present on the compressor suction port screen? | -- | ||||||||||||||||
13 |
Is the repair complete? | -- | -- | |||||||||||||||
14 |
Are the repairs completed? | -- | -- | |||||||||||||||
15 | Take readings of the low and high side pressures as well as the IP center outlet air temperatures after repairs are performed. Compare the pressures and IP outlet temperatures to those listed in the A/C Performance Table. Refer to Cooling Insufficient - Air Conditioning (A/C) System . Are the readings within the specified ranges? | -- | ||||||||||||||||
16 | Operate the system in order to verify the repair. Did you correct the condition? | -- | Go to Step 17 | Go to Symptoms in HVAC Systems - Manual | ||||||||||||||
17 |
Is the action complete? | -- | System OK | -- |