Removal Procedure
- Remove the instrument
panel cluster trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument Panel, Gages and Console.
- Remove the screws from the headlamp switch housing.
- Remove the headlamp switch housing from the instrument panel.
- Disconnect the electrical connector from the headlamp switch .
- Remove the headlamp switch from the headlamp switch housing.
Installation Procedure
- Install the headlamp switch
to the headlamp switch housing, pressing into place until fully seated.
- Connect the electrical connector to the headlamp switch.
- Install the headlamp switch housing to the instrument panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the headlamp switch housing screws.
Tighten
Tighten the headlamp housing switch screws to 2 N·m (18 lb in).
- Install the instrument panel cluster trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gages and Console.