Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems. |
2 |
Do the backup lamps turn on? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the test lamp turn on? | Go to Step 4 | Go to Step 9 |
4 | Install a 3A fused jumper across the switched side of the backup lamps relay at the RH I/P accessory wiring junction block. Do the backup lamps turn on? | Go to Step 5 | Go to Step 6 |
5 | Replace the backup lamp relay. Did you complete the repair? | Go to Step 10 | -- |
6 | Inspect for a short to ground in the backup lamps switched circuit. Did you find a short to ground in the circuit? | Go to Step 7 | Go to Step 8 |
7 | Repair a short to ground in the backup lamps switched circuit. Did you complete the repair? | Go to Step 10 | -- |
8 | Repair a poor connection or an open in the backup lamps switched circuit. Has the repair been made? | Go to Step 10 | -- |
9 | Replace the RH I/P accessory wiring junction block. Did you complete the repair? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | Go to Step 2 |