Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting systems. |
2 |
Do the courtesy lamps turn on? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Inspect the TRK/ROOF BRP Fuse. Is the fuse Open? | Go to Step 5 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 7 |
5 |
Did you complete the repair? | Go to Step 8 | -- |
6 | Repair a poor connection or open in the B+ feed for the courtesy lamps. Did you complete the repair? | Go to Step 8 | -- |
7 | Replace the RH I/P Accessory Wiring Junction Block. Did you complete the repair? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | Go to Step 2 |