The ignition switch supplies ignition 1 voltage to the inflatable restraint sensing and diagnostic module (SDM) at terminal A1 of connector C1 using the SDM Fuse. The ignition switch also supplies ignition 1 voltage to the instrument cluster. The AIR BAG warning lamp is controlled by the SDM via Class 2 serial data. When the ignition switch is first turned ON, the instrument cluster flashes the AIR BAG warning lamp seven times. Next, the SDM performs tests on the SIR system then commands the instrument cluster to turn OFF the AIR BAG warning lamp after it has flashed seven times. If the ignition 1 voltage is outside of the normal operating voltage range (9-16 V), the SDM will command the instrument cluster to turn ON the AIR BAG warning lamp with no DTCs present.
The loss of serial data communication between the SDM and the instrument cluster will cause the AIR BAG warning lamp to come ON solid. Refer to Data Link Communications Circuit Description in Data Link Communications.
The number(s) below refer to the step number(s) on the diagnostic table.
This step checks to see if the AIR BAG warning lamp flashes seven times when the ignition is turned ON.
This step checks to see if the scan tool can communicate with the instrument panel cluster (IPC).
This step checks to see if the ignition voltage to the SDM is greater than 9 V.
This step checks to see if the ignition voltage to the SDM is greater than 16 V.
This step checks the SDM wiring harness.
This step checks to see if there is an open or a high resistance in the B+ feed circuit to the SDM.
This step checks to see if there is an open or a high resistance in the B+ feed circuit to the SDM Fuse.
This step determines if there is an open or a high resistance in the SDM ground circuit or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform A Diagnostic System Check - SIR? | -- | Go to Step 2 | Go to cell-id="57882">A Diagnostic System Check - SIR> | ||||||
Does the AIR BAG warning lamp flash seven times? | -- | Go to Step 4 | Go to Step 3 | |||||||
3 | Replace the instrument cluster. Refer to cell-id="50650">Instrument Panel (IP) Cluster Replacement> in Instrument Panel, Gauges and Console. Did you complete the replacement? | -- | Go to Step 16 | -- | ||||||
Does the scan tool communicate with the IPC? | -- | Go to Step 5 | Go to cell-id="11033">Scan Tool Does Not Communicate with Class 2 Device> in Data Link Communications | |||||||
Use the scan tool to request the SIR data list display. Does the scan tool indicate that the ignition voltage is greater than the specified value? | 9 V | Go to Step 6 | Go to Step 7 | |||||||
Does the scan tool indicate that the ignition voltage is greater than the specified value? | 16 V | Go to cell-id="37779">A Diagnostic System Check - Starting and Charging> in Engine Electrical | Go to Step 15 | |||||||
Does the SDM wiring harness connector exhibit any sings of corrosion, terminal damage, or poor connections? | -- | Go to Step 8 | Go to Step 9 | |||||||
8 | Replace the SDM wiring harness connector. Refer to cell-id="61973">Connector Repairs> in Wiring Systems. Did you complete the repair | -- | Go to Step 16 | -- | ||||||
Does the resistance measure less than the specified value? | 0.5 ohms | Go to Step 11 | Go to Step 10 | |||||||
10 | Locate and repair an open or a high resistance in the B+ feed circuit from the SDM Fuse to the SDM. Did you complete the repair? | -- | Go to Step 16 | -- | ||||||
Does the voltage measure near the specified value? | 12 V | Go to Step 13 | Go to Step 12 | |||||||
12 | Locate an open or a high resistance in the B+ feed circuit to the SDM Fuse. Did you complete the repair? | -- | Go to Step 16 | -- | ||||||
Does the resistance measure less than the specified value? | -- | Go to Step 15 | Go to Step 14 | |||||||
14 | Locate and repair an open or a high resistance in the SDM ground circuit. Did you complete the repair? | -- | Go to Step 16 | -- | ||||||
15 | Replace the SDM. Refer to cell-id="57768">Inflatable Restraint Sensing and Diagnostic Module Replacement> or cell-id="57768">Inflatable Restraint Sensing and Diagnostic Module Replacement> . Did you complete the replacement? | -- | Go to Step 16 | -- | ||||||
16 |
Did you complete the action? | -- | Go to cell-id="57882">A Diagnostic System Check - SIR> | -- |