Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the power window operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify that the power window lockout function is inoperative. Does the system operate properly? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the test light illuminate? | -- | Go to Step 5 | Go to Step 4 |
4 | Replace the left front window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | -- | Go to Step 6 | -- |
5 | Repair the short to B+ in the power window lockout control circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Symptoms |