Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems. |
2 |
Are the courtesy lamps off? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Remove the BATT rundown protection relay. Do the courtesy lamps turn off? | Go to Step 4 | Go to Step 5 |
4 | Replace the BATT rundown protection relay. Did you complete the repair? | Go to Step 8 | -- |
5 |
Do the courtesy lamps turn off? | Go to Step 6 | Go to Step 7 |
6 | Replace the RH I/P Accessory Wiring Junction Block. Did you complete the repair? | Go to Step 8 | -- |
7 | Repair a short to B+ on the courtesy lamps switched B+ feed circuit. Did you complete the repair? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | Go to Step 2 |