The body control module (BCM) controls the I/P courtesy lamps through the courtesy lamps supply voltage circuit. The BCM grounds courtesy lamps low control circuit which completes the I/P courtesy lamps ground circuit, and the lights illuminate.
The BCM must be commanding the courtesy lamps feature OFF.
• | The BCM detects that the output for the courtesy lamps supply voltage circuit is low when it is expected to be high. |
• | The condition above must be present for more than 0.3 seconds. |
The BCM stores DTC B2617 in memory.
• | A current DTC 2617 will clear if the short to ground or open in the courtesy lamps supply voltage circuit is no longer detected by the BCM. |
• | A history DTC B2617 will clear after 100 consecutive ignition cycles if the condition for the malfunction is no longer present nor any other malfunction in the BCM is detected. |
• | If the DTC B2617 is a history DTC, the fault may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
• | The following conditions may cause an intermittent malfunction to occur: |
- | An intermittent short to ground or open in the courtesy lamps supply voltage circuit. |
- | Either I/P courtesy lamp is intermittently shorted to ground or open internally. |
- | The BCM is intermittently shorted to ground or open internally. |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Dimming Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do the footwell lamps turn ON and OFF with each command? | Go to Diagnostic Aids | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 10 |
4 |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 5 |
5 | Does the test lamp remain illuminated with each command? | Go to Step 7 | Go to Step 6 |
6 | Test the courtesy lamps low control circuit for high resistance or an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
7 | Test the courtesy lamps low control circuit for a short to ground. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at each I/P courtesy lamp. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the BCM. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Repair the high resistance or an open in the courtesy lamps supply voltage circuit of the footwell lamps. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
11 | Replace the inoperative I/P courtesy lamp. Refer to Instrument Panel Courtesy Lamp Bulb Replacement Did you complete the replacement? | Go to Step 13 | -- |
12 |
Important: Perform the set up procedure for the BCM. Refer to Body Control Module (BCM) Programming/RPO Configuration in Body Control System. Replace the BCM. Refer to Body Control Module Replacement in Body Control System. Did you complete the replacement? | Go to Step 13 | -- |
13 |
Does the DTC reset? | Go to Step 2 | System OK |