• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ignition Circuit to Deactivation Solenoids | P0102, P0480, P0481, P0645, P3401, P3417, P3433 | P0102, P0480, P0481, P0645, P3401, P3417, P3433 | P0690 | -- |
Deactivation Solenoid Control Circuits | P3401, P3417, P3433 | P3401, P3417, P3433 | P0690, P3401, P3417, P3433 | -- |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Vehicle traveling at 40 MPH, under a light load and steady throttle input. Normal Range: V3 mode | |||
Cylinder Deactivation System Command | V6 mode | V6 mode | -- |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Vehicle traveling at 40 MPH, under a light load and steady throttle input Normal Range: ON | |||
Cylinder 1, 3, 5 Deactivation Solenoid Command | OFF | OFF | -- |
Each of the 3 valve lifter oil manifold (VLOM) solenoid windings, are connected in parallel to a fused ignition circuit, supplied by the powertrain relay, in the underhood fuse block. The control circuit for each solenoid is connected to an individual low side driver, internal to the engine control module (ECM). Each low side driver has its own fault detection circuit, which monitors the solenoid control circuit for an incorrect voltage level. If an incorrect voltage level, such as an open/high resistance, or short to ground is detected, the low side driver will turn OFF, and the fault detection circuit will communicate the condition to the central processor internal to the ECM. These DTCs will set when the ECM detects an incorrect voltage level on the ignition circuit, the solenoids, or a solenoid control circuit, after the ignition switch is turned ON. If a VLOM solenoid control circuit DTC is set, the ECM will command V6 mode, turn ON the malfunction indicator light (MIL), and turn OFF the fuel injector for that cylinder, resulting in an engine misfire.
• | The engine speed is between 450-6,400 RPM. |
• | The ignition voltage is between 9-18 volts. |
• | DTCs P3401, P3417, and P3433 run continuously when the above conditions are met. |
• | The ECM detects that the commanded state of the low side driver and the actual voltage level of the control circuit do not match. |
• | The condition is present for 20 out 25 sample counts. |
• | DTCs P3401, P3417, and P3433 are type B DTC. |
• | The engine will return to V6 mode. |
• | The fuel injector will turn OFF for the cylinder that has a cylinder deactivation DTC set. |
DTCs P3401, P3417, and P3433 are type B DTC.
The valve lifter oil manifold (VLOM) solenoids are assigned to the following engine cylinders:
• | Solenoid #1 = Cylinder #1 |
• | Solenoid #2 = Cylinder #3 |
• | Solenoid #3 = Cylinder #5 |
Important: This test procedure requires that the vehicle battery has passed a load test and is completely charged. Refer to Battery Inspection/Test .
⇒ | If the total circuit resistance exceeds 22 ohms, then an open/high resistance condition exists in the VLOM solenoid circuit. |
Cylinder Deactivation (Active Fuel Management) System Description
EN-46999 DoD Tester
Ignition ON, engine OFF, command each VLOM solenoid ON and OFF several times using the scan tool. Listen for the VLOM solenoids to turn ON and OFF.
⇒ | If the vehicle passes the Circuit/System Verification Test, then operate the vehicle within the conditions for running the DTC. You may also operate the vehicle within the conditions that are captured in the Freeze Frame/Failure Records Data List. |
Important: Perform the Circuit/System Verification first.
⇒ | If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. |
⇒ | If the circuit tests normal and the ignition circuit fuse is open, remove the upper intake manifold and inspect the remainder of the harness. Refer to Upper Intake Manifold Replacement . |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit test normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage, or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the resistance is not within the specified range for each solenoid, replace the VLOM assembly. |
⇒ | If less than infinite resistance, replace the VLOM assembly. |
⇒ | If the function does not perform as specified, replace the VLOM assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |