• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Display Parameters | Normal Range | Short to Ground | Open/High Resistance | Short to Voltage |
---|---|---|---|---|
Operating Conditions: Ignition ON, engine OFF, powertrain relay commanded ON. | ||||
EC Ignition Powertrain Relay Circuit Status | OK/Incomplete | Short to GRN/Open | Short to GRN/Open | Short to B+ |
EC Ignition Powertrain Relay Command | ON | ON | ON | ON |
EC Ignition Powertrain Relay Feedback Signal | 12-12.9 V | 0.0 V | 0.0 V | 12-12.9 V |
The powertrain relay is a normally open relay. The relay armature is held in the open position by spring tension. Battery positive voltage is supplied directly to the relay coil and the armature contact at all times. The engine control module (ECM) supplies the ground path to the relay coil control circuit via an internal integrated circuit called an output driver module (ODM). The ODM output control is configured to operate as a low side driver for the powertrain relay. The ODM for the powertrain relay also incorporates a fault detection circuit, which is continuously monitored by the ECM. When the ECM commands the powertrain relay ON, ignition 1 voltage is supplied to the ECM, and to several additional circuits.
This test procedure requires that the vehicle battery has passed a load test and is completely charged. Refer to Battery Inspection/Test .
• | J 35616 Connector Test Adapter Kit |
• | J 43244 Relay Puller Pliers |
Important: On the scan tool, the powertrain relay is referred to as the EC ignition relay.
⇒ | If the vehicle passes the Circuit/System Verification test, then operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that are captured in the Freeze Frame/Failure Records Data list. |
⇒ | If the test lamp illuminates, test the relay coil control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp illuminates, test the relay ignition 1 voltage circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp does not illuminate, test the relay coil B+ circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the relay switch B+ circuit for a short to ground or an open/high resistance. If the circuits test normal and the fuse for the ignition 1 voltage circuit is open, test the ignition 1 voltage circuit to the ECM for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always ON, test the relay coil control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the relay coil control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the parameter does not display B+, test the ignition 1 voltage circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | Terminal 30 and 86 |
• | Terminal 30 and 87 |
• | Terminal 30 and 85 |
• | Terminal 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |