GM Service Manual Online
For 1990-2009 cars only

Blower Motor Replacement for Chevrolet Omega VE 2008

Blower Motor Replacement LHD

Removal Procedure

  1. Remove the right closeout insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side .
  2. Remove the instrument panel (I/P) compartment. Refer to Instrument Panel Compartment Replacement .

  3. Object Number: 1951025  Size: SH
  4. Disconnect the blower motor electrical connector.

  5. Object Number: 1951027  Size: SH
  6. Disconnect the blower motor processor electrical connector.

  7. Object Number: 1951030  Size: SH
  8. Remove the blower motor retaining screws (1).

  9. Object Number: 1951035  Size: SH
  10. Remove the blower motor.

Installation Procedure


    Object Number: 1951035  Size: SH
  1. Install the blower motor.
  2. Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1951030  Size: SH
  3. Install the blower motor retaining screws (1).
  4. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).


    Object Number: 1951027  Size: SH
  5. Connect the blower motor processor electrical connector.

  6. Object Number: 1951025  Size: SH
  7. Connect the blower motor electrical connector.
  8. Install the I/P compartment. Refer to Instrument Panel Compartment Replacement .
  9. Install the right closeout insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side .

Blower Motor Replacement RHD

Removal Procedure

    Caution: Refer to Safety Glasses Caution in the Preface section.

  1. Remove the glove box assembly. Refer to Instrument Panel Compartment Replacement .
  2. Remove the left floor air outlet duct. Refer to Floor Air Outlet Duct Replacement - Left Side .

  3. Object Number: 1950927  Size: SH
  4. Disconnect the blower motor electrical connector (1).

  5. Object Number: 1951004  Size: SH
  6. Remove the blower motor to blower assembly retaining screws (1).

  7. Object Number: 1950930  Size: SH
  8. Remove the blower motor (2) from the blower assembly (1).

Installation Procedure


    Object Number: 1950930  Size: SH
  1. Install the blower motor (2) to the blower assembly (1).
  2. Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1951004  Size: SH
  3. Install the blower motor to blower assembly retaining screws (1).
  4. Tighten
    Tighten the screws to 2 N·m(18lb in).


    Object Number: 1950927  Size: SH
  5. Connect the blower motor electrical connector (1).
  6. Install the left floor air outlet duct. Refer to Floor Air Outlet Duct Replacement - Left Side .
  7. Install the glove box assembly. Refer to Instrument Panel Compartment Replacement .