The engine control module (ECM) monitors the position of the exhaust gas recirculation (EGR) valve through the EGR valve position sensor. The EGR valve position sensor sends a feedback voltage on the signal circuit to the ECM. The EGR position sensor voltage varies depending on the position of the EGR valve. If the voltage on the signal circuit of the EGR valve position sensor is pulled higher than a calibrated value, DTC P0406 sets.
This diagnostic procedure supports the following DTC:
DTC P0406 Exhaust Gas Recirculation (EGR) Position Sensor Circuit High Voltage
• | The ignition 1 voltage is between 11.7-16 volts. |
• | DTC P0406 runs continuously when the above condition is met. |
The ECM detects the voltage on the signal circuit of the EGR valve position sensor is more than 4.9 volts for more than 10 seconds.
• | The control module illuminates the malfunction indicator lamp (MIL) when the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Freeze Frame/Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Engine Controls Schematics Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views | ||||
1 | Did you perform the Diagnostic System Check - Engine Controls? | -- | Go to Step 2 | |
2 |
Did DTC P0406 fail this ignition? | -- | Go to Step 4 | Go to Step 3 |
3 |
Did the DTC fail this ignition? | -- | Go to Step 4 | Go to Intermittent Conditions |
4 |
Is the voltage more than the specified value? | 0 V | Go to Step 6 | Go to Step 5 |
5 |
Important: Use the J 35616-200 Test Lamp Kit for this test. If the J 35616-200 is not available, use a test lamp that measures between 25-30 ohms. Connect a test lamp between battery voltage and the low reference circuit of the EGR valve position sensor. Does the test lamp illuminate? | -- | Go to Step 8 | Go to Step 7 |
6 | Test the signal circuit of the EGR valve position sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 9 |
7 | Test the low reference circuit of the EGR valve position sensor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 9 | |
8 | Test for shorted terminals and poor connections at the EGR valve. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 10 |
9 | Test for shorted terminals and poor connections at the engine control module (ECM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 11 |
10 | Replace the EGR valve. Refer to Exhaust Gas Recirculation Valve Replacement . Did you complete the replacement? | -- | Go to Step 12 | -- |
11 | Replace the ECM. Refer to Engine Control Module Replacement . Did you complete the replacement? | -- | Go to Step 12 | -- |
12 |
Did the DTC fail this ignition? | -- | Go to Step 2 | Go to Step 13 |
13 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | -- | System OK |