Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Remove the instrument panel under cover.
- Remove the bolts and the daytime running lamp module.
- Disconnect the electrical connector.
Installation Procedure
- Connect the electrical connector.
Notice: Refer to Fastener Notice in the Preface section.
- Install the daytime running lamp module with the bolts.
Tighten
Tighten the daytime running lamp module bolts to
2 N·m (18 lb in).
- Install the instrument panel under cover.
- Connect the negative battery cable.