Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect other instrumentation lights. Are other lights OFF? | -- | Instrument Panel Illumination Lamps Inoperative in Instrument Panel, Gages and Console | Go to Step 2 |
2 |
Does the voltage measure within the specified range? | 11-14 V | Go to Step 4 | Go to Step 3 |
3 | Repair the wiring harness between splice S204 and controller connector terminal A4 or between splice S203 and controller connector terminal A3 Did you complete the repair? | -- | System OK | -- |
4 | Inspect the illumination lamps. Is 1 lamp burned out? | -- | Go to Step 5 | System OK |
5 | Replace the burned out illumination lamp. Did you complete the replacement? | -- | System OK | -- |