Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Remove the glove box. Refer to
Instrument Panel Storage Compartment Replacement
in Instrument
panel, Gages and Console.
- Remove the carpet to prevent stains.
- Disconnect the blower motor electrical connector and resistor connector.
- Remove the screws that secure the motor to the heater/air distributor
case.
- Remove the motor, the seal, and the shock mount pads
from the heater/air distributor case by gently pulling the motor straight down and
out.
Installation Procedure
- Install the blower motor and the seal with the shock
mount pads in the heater/air distributor case. Hold the blower motor in position.
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to secure the blower motor to the heater/air distributor
case.
Tighten
Tighten the blower motor retaining screws to 1.2 N·m
(11 lb in).
- Connect the blower motor electrical connector and resistor connector.
- Connect the negative battery cable.
- Confirm that the blower motor operates properly.
- Replace the glove box. Refer to
Instrument Panel Storage Compartment Replacement
in Instrument
Panel, Gages and Console.