This code will set if the output of the sun sensor indicates a probable short circuit or an open in the sensor or the associated wiring harness, or a malfunction of the automatic temperature control (ATC) controller.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is there any sign of damage in the wiring or connector or does the resistance measured equal the value specified? | 0 ohms | Go to Step 2 | Go to Step 3 |
2 | Repair the damaged wiring or the connector, or replace the sun sensor as required. Did you complete the repair or replacement? | -- | System OK | -- |
3 |
Is the voltage measured less than or equal to the specified value? | 4 V | Go to Step 7 | Go to Step 4 |
4 | Inspect the terminals on the sun sensor connector. Is any problem found with the connector? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the connector terminals or replace the sun sensor or ATC controller as required. Did you complete the repair or replacement? | -- | System OK | -- |
6 |
Does this display indicate the continuing presence of a code 5 condition? | -- | Go to Step 9 | System OK |
7 |
Is the voltage measured less than or equal to the specified value? | 4 V | Go to Step 9 | Go to Step 8 |
8 |
Did you complete the repair? | -- | System OK | -- |
9 | Replace the ATC controller. Did you complete the replacement? | -- | System OK | -- |