This DTC will set if the output of the ambient air temperature sensor indicates a probable short circuit or an open in the sensor or the associated wiring harness, or a malfunction of the automatic temperature control (ATC) controller.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the resistance measured equal to the specified range at 20-25°C (68-77°F)? | 2600-2100 Ω | Go to Step 5 | Go to Step 2 |
2 |
Is there a problem with the wiring or the connector? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the problem found in the ambient air sensor wiring or the connector. Did you complete the repair? | -- | System OK | -- |
4 | Replace the ambient air sensor. Did you complete the replacement? | -- | System OK | -- |
5 |
Is the voltage measured greater than or equal to the specified value? | 4 V | Go to Step 7 | Go to Step 6 |
6 |
Does this display indicate the continuing presence of a DTC 2 condition? | -- | Go to Step 8 | System OK |
7 |
Is the voltage measured less than or equal to the specified value? | 4 V | Go to Step 8 | Go to Step 9 |
8 | Replace the ATC controller. Did you complete the replacement? | -- | System OK | -- |
9 |
Did you complete the repair? | -- | System OK | -- |