Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: Component Connector End Views | ||||
1 |
Does the digit go ON and OFF? | -- | Go to Step 2 | Go to Step 3 |
2 | Perform the Diagnostic System Check - HVAC Systems Automatic. Does the display indicate any error codes? | -- | -- | |
3 | Inspect fuse F7 in the instrument panel (I/P) fuse block. Is the fuse in good condition? | -- | Go to Step 5 | Go to Step 4 |
4 | Replace fuse F7. Did you complete the replacement? | -- | System OK | -- |
5 | Inspect fuse EF3 in the engine fuse block. Is this fuse in good condition? | -- | Go to Step 7 | Go to Step 6 |
6 | Replace fuse EF3. Did you complete the replacement? | -- | System OK | -- |
7 |
Is the voltage measured within the specified range? | 11-14 V | Go to Step 15 | Go to Step 8 |
8 | Measure the voltage between the ground and terminal 86 (Brown) at the blower relay. Is the voltage measured within the specified range? | 11-14 V | Go to Step 10 | Go to Step 9 |
9 |
Did you find and correct the condition? | -- | System OK | -- |
10 | Measure the voltage between the ground and terminal 30 (Red) at the blower relay. Is the voltage measured within the specified range? | 11-14 V | Go to Step 12 | Go to Step 11 |
11 |
Did you find and correct the condition? | -- | System OK | -- |
12 |
Does the ohmmeter show the specified value? | 0 Ω | Go to Step 14 | Go to Step 13 |
13 | Repair any condition found in terminal 85 at the relay connector, circuit (Black), connector C201, or ground G201. Did you complete the repair? | -- | System OK | -- |
14 | Replace the blower relay. Did you complete the replacement? | -- | System OK | -- |
15 |
Is the voltage measured within the specified range? | 11-14 V | Go to Step 17 | Go to Step 16 |
16 |
Did you find and correct the condition? | -- | System OK | -- |
17 | Measure the resistance between the connector terminals on the blower motor. Does the resistance measured equal the specified value? | 5 Ω | Go to Step 19 | Go to Step 18 |
18 | Replace the blower motor. Did you complete the replacement? | -- | System OK | -- |
19 | Measure the resistance of the circuit (Violet) between terminal 2 of the blower connector and terminal 30 of the MAX HI relay and terminal 6 of the power transistor. Does the resistance measured equal the specified value? | 0 Ω | Go to Step 21 | Go to Step 20 |
20 | Repair the problem in the circuit (Violet). Did you complete the repair? | -- | System OK | -- |
21 | Measure the resistance of the circuit (Black) from terminal 3 of the power transistor connector to ground. Does the resistance measured equal the specified value? | 0 Ω | Go to Step 23 | Go to Step 22 |
22 |
Did you find and correct the condition? | -- | System OK | -- |
23 | Replace the automatic temperature control (ATC) controller. Did you complete the replacement? | -- | System OK | -- |