GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

    Caution: Refer to Battery Disconnect Caution in the Preface section.


    Object Number: 1308422  Size: SH
  1. Disconnect the negative battery cable.
  2. Remove the glove box. Refer to Instrument Panel Storage Compartment Replacement .
  3. Remove the actuating rod by snapping the rod out of the lever with needle-nose pliers.
  4. Disconnect the electrical connector.
  5. Remove a screw and the bracket mounting high-blower relay.
  6. Remove the motor retaining screws.
  7. Remove the motor.

Installation Procedure

    Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1308436  Size: SH
  1. Install the motor with the retaining screws.
  2. Install the actuating rod.
  3. Connect the electrical connector.
  4. Install the bracket mounting high-blower relay with a screw.
  5. Remove the glove box. Refer to Instrument Panel Storage Compartment Replacement .
  6. Connect the negative battery cable.