Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
- Open and suitably support the liftgate.
- Disconnect liftgate door grommet.
- Disconnect the electrical connector.
- Disconnect the liftgate washer hose.
- Remove the liftgate struts. Refer to
Liftgate Strut Replacement.
- With the aid of an assistant, remove the bolts and the liftgate from the hinges.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- With the aid of an assistant, install the liftgate to the hinges with the bolts and tighten to
20 N·m (15 lb ft).
- Install the liftgate struts. Refer to
Liftgate Strut Replacement.
- Connect the liftgate washer hose.
- Connect the electrical connector.
- Connect the liftgate door grommet.
- Connect the negative battery cable.