Installation Procedure
- Install the exhaust manifold gasket.
- Install the exhaust manifold.
Notice: Refer to Fastener Notice in the Preface section.
- Install the exhaust manifold retaining nuts and tighten in the sequence shown.
Tighten
Tighten the exhaust manifold retaining nuts 22 N·m (16 lb ft).
- Install the exhaust flex pipe retaining nuts to the exhaust manifold studs.
Tighten
Tighten the exhaust flex pipe-to-exhaust manifold retaining nuts to 35 N·m (26 lb ft).
- Install the exhaust manifold heat shield.
- Install the exhaust manifold heat shield bolts.
Tighten
Tighten the exhaust manifold heat shield bolts to 8 N·m (71 lb in).
- Connect the oxygen sensor (O2S) connector, if equipped.
- Connect the negative battery.