Step | Action | Yes | No |
---|---|---|---|
1 | Verify the customer's complaint. Are the customer's concerns verified? | Go to Step 2 | System OK |
2 | Move controls other than the temperature adjustment. Is an excessive effort required to move the controls? | Go to Step 15 | Go to Step 3 |
3 | Move the temperature control. Is an excessive effort required to move the controls? | Go to Step 6 | Go to Step 4 |
4 | Move the temperature control. Does the temperature door move too easily? | Go to Step 5 | System OK |
5 | Remove the cable from the controller. Does the control knob turn freely without the click stops? | Go to Step 15 | -- |
6 | Inspect the cables for improper routing, kinks, wiring interference, or other instrument panel interference. Is there a problem? | Go to Step 7 | Go to Step 8 |
7 | Repair as needed. Did you complete the repair? | System OK | - |
8 |
Is there any door binding? | Go to Step 9 | Go to Step 12 |
9 | Inspect a binding door for shaft alignment, a bent shaft, a bent door, or a warped case. Is the door seal OK? | Go to Step 10 | Go to Step 11 |
10 |
Did you find and correct the condition? | System OK | -- |
11 | Repair the door seal as needed. Did you complete the repair? | System OK | -- |
12 | Inspect for control binding. Does the control bind? | Go to Step 14 | Go to Step 13 |
13 |
Did you find and correct the condition? | System OK | -- |
14 |
Does the control bind? | Go to Step 15 | Go to Step 16 |
15 | Replace the control. Did you complete the replacement? | System OK | -- |
16 | Replace the cable. Did you complete the replacement? | System OK | -- |