The transmission fluid temperature (TFT) sensor is a positive temperature coefficient thermistor (temperature sensitive resistor) that provides information to the transmission control module (TCM) regarding transaxle fluid temperature. The temperature sensor is located in valve body. Calculated temperature is a factor used to determine the shift time and shift delay time.
The internal electrical resistance of the sensor varies in relation to the operating temperature of the transaxle fluid.
The TCM sends a 5-volt reference signal to the temperature sensor and measures the voltage rise in the electrical circuit. A higher fluid temperature creates a higher resistance in the temperature sensor, thereby measuring a higher voltage signal.
The TCM measures this voltage as another input to help control line pressure, shift schedules and TCC apply. When transaxle fluid temperature reaches 120°C (248°F) the TCM enters "hot mode". At greater temperatures the TCM modifies transaxle shift schedules and TCC apply in an attempt to reduce fluid temperature by reducing transaxle heat generation.
This diagnostic procedure supports the following DTC:
DTC P0218 Transmission Fluid Overtemperature
• | The calculated temperature is compared with the predetermined min. and max. value. |
• | If the temperature is less than min. value or greater than max value then the current temperature is regarded as of range and the corresponding error but will be set. |
• | No lamp control required but diagnostic information should be stored immediately when malfunction is detected. |
• | TCM assumes the transaxle fluid temperature is 60°C (124°F). |
• | No influence on driveability. |
Using a scan tool can clear history DTCs.
When DTC P0218 sets, the possible cause of fault could be Transaxle Temperature Sensor.
Step | Action | Values | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||
2 |
Did either of the fail conditions occur? | -- | Go to Step 3 | Go to Diagnostic Aids | ||||
3 |
Is the resistance at the specified value? | TFT 25°C (77°F) 990 ohms | Go to Step 7 | Go to Step 4 | ||||
4 |
Was a problem found? | -- | Go to Step 5 | Go to Step 6 | ||||
5 | Replace the automatic transaxle wiring harness. Is the replacement complete? | -- | System OK | -- | ||||
6 | Replace the TFT sensor. Is the action complete? | -- | System OK | -- | ||||
7 |
Is the resistance approximately equal to the specified value? | 0 ohms | Go to Step 9 | Go to Step 8 | ||||
8 |
Is the repair complete? | -- | System OK | -- | ||||
9 |
Is the voltage within the specified value? | 9-16 V | Go to Step 10 | Go to Step 11 | ||||
10 |
Is the repair complete? | -- | System OK | -- | ||||
11 | Replace the TCM. Refer to Transmission Control Module Replacement . Is the replacement complete? | -- | Go to Step 12 | -- | ||||
12 |
Has the last test failed or is the current DTC displayed? | -- | Go to Step 2 | System OK |