Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Recover the refrigerant Refer to
Refrigerant Recovery and Recharging
.
- Remove the suction hose/liquid pipe block retaining nuts at the fire wall.
- Remove the expansion valve connector block retaining stud bolts.
- Remove the expansion valve.
- Discard the O-rings.
Installation Procedure
- Clean the grooves that fit the O-rings of any dirt or contamination.
- Install new O-rings on the evaporator tubes.
- Install a expansion valve onto the evaporator tubes.
Notice: Refer to Fastener Notice in the Preface section.
- Insert the expansion valve connector block retaining stud bolts.
Tighten
Tighten the expansion valve retaining stud bolts to 8 N·m (71 lb in).
- Install the suction hose/liquid pipe block retaining nuts.
Tighten
Tighten the suction hose/liquid pipe block-to-expansion valve retaining nuts to 14 N·m (10 lb ft).
- Connect the negative battery cable.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.