Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | BK | 1050 | Ground | ||||
2 | L-GN | 275 | Park/Neutral Position (PNP) Switch Signal | ||||
3 | D-GN | 286 | Shift Lock Control Solenoid | ||||
4 | PK | 239 | Ignition 1 Voltage |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | BK | 1050 | Ground | ||||
2 | L-GN | 275 | Park/Neutral Position (PNP) Switch Signal | ||||
3 | L-GN | 275 | Park/Neutral Position (PNP) Switch Signal | ||||
4 | D-GN | 286 | Automatic Transmission Shift Lock Solenoid Supply Voltage |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | -- | -- | Not Used | ||||
2 | YE | 43 | Accessory Voltage | ||||
3 | -- | -- | Not Used | ||||
4 | D-GN | 286 | Shift Lock Control Solenoid Control | ||||
5 | YE | 1075 | Park Neutral Position (PNP) Switch Signal | ||||
6 | BK | 250 | Ground | ||||
7 | L-BU | 20 | Stop Lamp Switch Signal | ||||
8 | L-GN | 275 | Park Neutral Position (PNP) Switch Signal | ||||
9 | -- | -- | Not Used |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | -- | -- | Not Used | ||||
2 | YE | 1075 | Park Neutral Position (PNP) Switch Signal | ||||
3 | -- | -- | Not Used | ||||
4 | BK | 250 | Ground | ||||
5 | D-GN | 286 | Shift Lock Control Solenoid Control | ||||
6 | L-GN | 275 | Park Neutral Position (PNP) Switch Signal | ||||
7 | OG/BK | 434 | Park Neutral Position (PNP) Switch Signal | ||||
8 | L-BU | 20 | Stop Lamp Switch Signal | ||||
9 | YE | 434 | Park Neutral Position (PNP) Switch Signal |