Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Charging System Check? | Go to Step 2 | Go to Charging System Check |
2 |
Does the charge indicator light? | Go to Step 8 | Go to Step 3 |
3 |
Does the charge indicator light? | Go to Step 5 | Go to Step 4 |
4 | Test for battery voltage at the instrument cluster connector 4 terminal 10. Is battery voltage present? | Go to Step 7 | Go to Step 6 |
5 | Repair the open in the YEL wire between the instrument cluster and the generator (including SP258). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Charging System Check | -- |
6 | Test for an open in BLK/ORN wire between junction block 2 and the instrument cluster. Is an open present? | Go to Step 13 | Go to Step 12 |
7 |
Is the repair complete? | Go to Charging System Check | -- |
8 | With the ignition switch ON test for battery voltage at the generator connector terminal 2. Is battery voltage present? | Go to Step 15 | Go to Step 9 |
9 | With the ignition switch ON, test for battery voltage at the multifunction alarm module connector 2 terminal 9. Is battery voltage present? | Go to Step 11 | Go to Step 10 |
10 |
Is battery voltage present? | Go to Step 14 | Go to Step 12 |
11 | Repair the open in the RED/BLU wire between the multifunction alarm module and the generator (including junction block 3). Is the repair complete? | Go to Charging System Check | -- |
12 | Replace junction block 2. Is the repair complete? | Go to Charging System Check | -- |
13 | Repair the open. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Charging System Check | -- |
14 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement . Is the repair complete? | Go to Charging System Check | -- |
15 | Repair or replace the generator. Refer to Generator Replacement and Generator Overhaul . Is the repair complete? | Go to Charging System Check | -- |