Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Heater Blower Controls System Check? | Go to Step 2 | |
2 |
Does the test lamp light? | Go to Step 14 | Go to Step 3 |
3 | Test for an open in the BLK/WHT wire between the blower motor and the blower motor resistor. Is an open present? | Go to Step 16 | Go to Step 4 |
4 | Test for an open in the BLK wire between the blower motor and the HTR relay in fuse and relay block 3. Is an open present? | Go to Step 15 | Go to Step 5 |
5 | Test that the HTR relay is open between terminals 4 and 5 and that there is continuity between terminals 4 and 2. Refer to Fuse and Relay Block 3 . Did the relay test OK? | Go to Step 6 | Go to Step 13 |
6 |
Is battery voltage present? | Go to Step 8 | Go to Step 7 |
7 | Test for an open in the RED/BLU wire between fuse and relay block 3 and the multifunction alarm module, including junction block 3. Is an open present? | Go to Step 15 | Go to Step 17 |
8 |
Is battery voltage present? | Go to Step 9 | Go to Step 10 |
9 | Test for an open in the WHT/BLK wire between the blower speed selector switch terminal 1 and G204. Is an open present? | Go to Step 15 | Go to Step 11 |
10 | Test for an open in the BLU/ORN wire between fuse and relay block 3 and the blower speed selector switch. Is an open present? | Go to Step 15 | Go to Step 13 |
11 |
Was an open found in any of the above tests? | Go to Step 12 | Go to Step 13 |
12 | Replace the blower speed selector switch. Refer to Blower Switch Replacement . Is the repair complete? | -- | |
13 | Replace the heater relay. Refer to Blower Motor Relay Replacement . Is the repair complete? | -- | |
14 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | |
15 | Repair the open. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | |
16 | Repair the open in the BLK/WHT wire between the blower motor and S200. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | |
17 | Replace the multi-function alarm module. Refer to Multifunction Alarm Module Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- |