GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

Were you sent here from the DRL System Check?

--

Go to Step 2

Go to Daytime Running Lights (DRL) System Check

2

  1. Start the engine.
  2. Disengage the parking brake.

Is the brake indicator on?

--

Go to Step 3

Go to Step 7

3

  1. Disconnect the parking brake switch connector. Refer to Parking Brake Indicator Switch Replacement in Park Brake for access.
  2. Start the engine.

Does the brake indicator stop illuminating and the headlamps light to the DRL mode?

--

Go to Step 4

Go to Step 5

4

Replace the parking brake switch. Refer to Parking Brake Indicator Switch Replacement in Park Brake.

Is the replacement complete?

--

Go to Daytime Running Lights (DRL) System Check

--

5

Test the RED/BLU wire between the DRL control module connector cavity 14 and the parking brake switch connector for a short to ground condition using a J 39200 .

Does the RED/BLU wire have a short to ground condition?

--

Go to Step 6

Go to Step 21

6

Repair the short to ground condition in the RED/BLU wire between the DRL control module connector cavity 14 and the parking brake switch connector. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

7

  1. Disconnect the DRL control module connector.
  2. Measure the voltage between cavity 22 of the DRL module connector to chassis ground using a J 39200 .

Is the voltage equal to the specified value?

B+

Go to Step 8

Go to Step 14

8

  1. Turn ignition to the ON position.
  2. Measure the voltage between cavity 23 of the DRL module connector to chassis ground using a J 39200 .

Is the voltage equal to the specified value?

B+

Go to Step 9

Go to Step 15

9

  1. Disconnect the DRL control module connector.
  2. With the engine running, measure the voltage between cavity 13 to chassis ground using a J 39200 .

Is the voltage equal to the specified value?

--

Go to Step 10

Go to Step 16

10

Test for continuity between cavity 12 of the DRL module connector and ground using a J 39200 .

Is there continuity to ground in the WHT/BLK wire?

--

Go to Step 11

Go to Step 17

11

Test for continuity between cavity 1 of the DRL module connector and ground using a J 39200 .

Is there continuity to ground in the WHT/BLK wire?

--

Go to Step 12

Go to Step 18

12

  1. Disconnect connector C3 of junction block 1.
  2. Test for continuity between cavity 11 of the DRL control module and cavity 2 of connector C3 of junction block 1 using a J 39200 .

Is there continuity in the RED/YEL wire?

--

Go to Step 13

Go to Step 19

13

Test for continuity between cavity 25 of the DRL control module and cavity 2 of connector C3 of junction block 1 using a J 39200 .

Is there continuity in the RED/YEL wire?

--

Go to Step 21

Go to Step 20

14

Repair the open in the BLU/YEL wire between cavity 22 of the DRL control module connector and cavity 10 of connector C3 of junction block 1. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

15

Repair the open in the RED/BLU wire between cavity 23 of the DRL control module connector and cavity 6 of connector C1 of junction block 3. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

16

Repair the open in the YEL wire between the DRL control module connector cavity 13 and SP258. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

17

Repair the open in the WHT/BLK wire between cavity 12 of the DRL control module connector and ground. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

18

Repair the open in the WHT/BLK wire between cavity 1 of the DRL control module connector and SP261. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

19

Repair the open in the RED/YEL wire between cavity 11 of the DRL control module connector and cavity 2 of connector C3 of junction block 1. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

20

Repair the open in the RED/YEL wire between cavity 25 of the DRL control module connector and SP261. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Daytime Running Lights (DRL) System Check

--

21

Replace the DRL control module. Refer to Daytime Running Lights (DRL) Control Module Replacement .

Is the replacement complete?

--

Go to Daytime Running Lights (DRL) System Check

--