Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the Interior Lights System Check? | -- | Go to Step 2 | |
2 | Will the dome lamp extinguish when the switch is in the OFF position? | -- | Go to Step 3 | Go to Step 4 |
3 |
Did you find a short to ground in the RED/WHT wire? | -- | Go to Step 5 | Go to Step 6 |
4 | Replace the dome lamp assembly. Refer to Dome Lamp Replacement . Is the repair complete? | -- | -- | |
5 | Repair the short to ground in the RED/WHT wire. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Test the RED/WHT wires from the multifunction alarm module to the door jamb switches for a short to ground. Are the RED/WHT wires shorted to ground? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair the short to ground in the damaged wires. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement in Instrument Panel, Gauges, and Console. Is the replacement complete? | -- | -- |