Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Does the power door lock/unlock function operate properly? | -- | Go to Step 2 | |
2 | Reprogram the RKE module. Refer to Transmitter Programming in Keyless Entry. Does the RKE system respond properly? | -- | Go to Step 3 | |
3 |
Does the wire have a short to ground? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair the short between terminal 8 of the RKE module connector and terminal 11 of connector C5 of the fuse and relay block 1. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the open between terminal 13 of the RKE module connector and terminal 2 of connector C4 of the junction block 2. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
7 | Test for a short using a J 39200 between terminal 1 of the connector and ground. Does a short exist between terminal 1 of the connector and ground? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair the short between terminal 1 of the RKE module connector and G200. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
9 |
Does a short to ground exist between terminal 10 and ground? | -- | Go to Step 10 | Go to Step 11 |
10 | Repair the short to ground between terminal 10 of the RKE module connector and G204. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
11 | Test for an open using a J 39200 between terminal 14 of the RKE module connector and SP261. Does an open exist? | -- | Go to Step 12 | Go to Step 13 |
12 | Repair the open between terminal 14 of the RKE module connector and SP261. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
13 | Replace the remote control door lock receiver. Refer to Remote Control Door Lock Receiver Replacement in Keyless Entry. Is the repair complete? | -- | -- |