Application
| Specification
|
Metric
| English
|
Starting System
|
| 15.5 mm
| 0.610 in
|
| 10.0 mm
| 0.394 in
|
- Brush Spring Tension - Standard
| 1.8-2.4 kg
| 4.0-5.3 lbs
|
- Brush Spring Tension - Minimum
| 1.2 kg
| 2.6 lbs
|
- Commutator Insulation Depth - Standard
| 0.60 mm
| 0.024 in
|
- Commutator Insulation Depth - Minimum
| 0.20 mm
| 0.008 in
|
- Commutator Outside Diameter - Standard
| 30 mm
| 1.18 in
|
- Commutator Outside Diameter - Minimum
| 29 mm
| 1.14 in
|
- Commutator Runout - Standard
| 0.05 mm
| 0.002 in
|
| Clockwise (as viewed from pinion)
|
| 9
|
| 1.4 watts
|
| 30 seconds
|
- Starter Current Draw, no load
| 90 amps at 11.5 volts
|
- Starter Current Draw, load, manual transaxle (9.1 N·m/80.5 lb in
of torque)
| 300 amps at 7.7 volts
|
- Starter Current Draw, load, automatic transaxle (10.4 N·m/92 lb in
of torque)
| 300 amps at 7.7 volts
|
- Locked Rotor - Manual Transaxle (18.6 N·m/13.8 lb ft)
| 780 amps at 4 volts
|
- Locked Rotor - Automatic Transaxle (25.5 N·m/18.8 lb ft)
| 980 amps at 4 volts
|
- Starter Solenoid Operating Voltage
| 8 volts minimum
|
- Solenoid Contact Plate Wear - Maximum
| 0.9 mm
| 0.035 in
|
| 12 volts
|