Removal Procedure
- Disconnect the electrical
connector (2) from the EVAP canister purge valve (4).
- Remove the 2 vapor lines (1) from the EVAP canister purge
valve.
- Remove the fastener (3) retaining the valve to the air
filter housing.
- Inspect the EVAP canister purge valve and the EVAP purge system
for carbon particle contamination before replacing the EVAP canister purge
valve. Refer to
Evaporative Emission System Cleaning
.
Installation Procedure
- Inspect the EVAP canister purge system for carbon particle contamination
before replacing the EVAP canister purge valve. Refer to
Evaporative Emission System Cleaning
.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the EVAP
canister purge valve (4) to the air filter housing with the fastener (3).
Tighten
Tighten the fastener to 8.8 N·m (77 lb in).
- Connect the 2 vapor hoses (1).
- Connect the electrical connector (2).