The inflatable restraint IP module deployment loop consists of an inflatable restraint IP module, the IP module high and IP module low circuits. A shorting bar is used in the inflatable restraint IP module connector which will short together the IP module - high and IP module low circuits when the connector is disconnected, this will help to prevent unwanted deployment of the inflator module during servicing. When the ignition is turned ON, the inflatable restraint sensing and diagnostic module (SDM) performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. If a malfunction is detected, a DTC will be stored.
Ignition 1 Voltage is within the normal operating voltage range.
The SDM detects a low resistance condition in the IP module deployment loop.
The SDM commands the AIR BAG indicator ON.
The condition responsible for setting the DTC no longer exists and the scan tool Clear DTCs function is used.
Thoroughly inspect the wiring and the connectors. An incomplete inspection of the wiring and the connectors may result in a misdiagnosis, causing a part replacement with the reappearance of the malfunction.
The following are possible causes of the malfunction:
• | A short between the IP module - high and the IP module - low circuits. |
• | A malfunctioning inflatable restraint IP module. |
• | An internal SDM malfunction. |
If an intermittent malfunction exists, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
Tests to see if the malfunction is caused by the inflatable restraint IP module.
Tests for a short between the IP Module High and IP Module Low circuits.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: SIR Schematics | |||
1 | Did you perform A Diagnostic System Check - SIR? | Go to Step 2 | |
2 | Is DTC B0105 set as a current DTC? | Go to Step 3 | Go to Diagnostic Aids |
3 |
Does the connector exhibit any signs of damage or corrosion? | Go to Step 4 | Go to Step 5 |
4 |
Did you complete the replacement? | Go to Step 10 | -- |
Does the scan tool indicate that DTC B0105 is current? | Go to Step 6 | Go to Step 8 | |
6 |
Did you find and correct the condition? | Go to Step 10 | Go to Step 7 |
Test for a short between the IP Module - High and the IP Module - Low circuits. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 | |
8 |
Did you complete the replacement? | Go to Step 10 | -- |
9 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | Go to Step 10 | -- |
10 |
Does the DTC reset? | Go to Step 2 | System OK |