The ignition switch supplies battery voltage to the AIR BAG indicator using the ECU-B fuse. The AIR BAG indicator is connected to the AIR BAG indicator control circuit of the SDM. When the ignition switch is first turned to the ON position, the SDM responds by illuminating the AIR BAG indicator for approximately six seconds while performing diagnostic tests on the SIR system.
Thoroughly inspect the wiring and the connectors. An incomplete inspection of the wiring and the connectors may result in a misdiagnosis, causing a part replacement with the reappearance of the malfunction.
The following are possible causes of the malfunction:
• | A short to ground in the diagnostic request circuit |
• | An internal SDM malfunction |
If an intermittent malfunction exists, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: SIR Schematics | |||
1 | Did you perform A Diagnostic System Check - SIR? | Go to Step 2 | |
2 |
Did you find and correct the condition? | Go to Step 4 | Go to Step 3 |
3 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | Go to Step 4 | -- |
4 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |