Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Were you sent here from the Exterior Lights System Check? | Go to Step 2 | |
2 | Verify that the hazard lamps are inoperative. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 |
Does the test lamp illuminate? | Go to Step 12 | Go to Step 13 |
5 | Using a test lamp, check the fuse and relay block 1, C5 cavity 3 to ground. Does the test lamp illuminate? | Go to Step 7 | Go to Step 6 |
6 | Check the HAZARD fuse, located in fuse and relay block 1. Does an open exist in the 10 A HAZARD fuse? | Go to Step 8 | Go to Step 11 |
7 | Repair the open in the battery positive voltage circuit between the relay block 1, C5 cavity 3 and hazard switch cavity 6. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 23 | -- |
8 |
Is there high resistance to ground in the battery positive voltage circuit? | Go to Step 10 | Go to Step 9 |
9 | Replace the 10 A hazard fuse. Is the repair complete? | Go to Step 23 | -- |
10 | Repair the short to ground condition between fuse and relay block 1 connector C 5 cavity 3 and ground. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 23 | -- |
11 | Replace the fuse and relay block 1. Refer to Underhood Electrical Center or Junction Block Replacement in Wiring Systems. Is the repair complete? | Go to Step 23 | -- |
12 | Using a test lamp, check junction block 1 turn/hazard flasher cavity 2 to ground. Does the test lamp illuminate? | Go to Step 14 | Go to Step 15 |
13 | Replace the hazard switch. Refer to Hazard and Turn Signal Flasher Replacement in Instrument Panel, Gages, and Console. Is the repair complete? | Go to Step 23 | -- |
14 | Using a test lamp, check junction block 1 turn/hazard flasher cavity 3 to ground. Does the test lamp illuminate? | Go to Step 16 | Go to Step 17 |
15 | Repair the open in the flasher feed circuit between the junction block 1 turn/hazard flasher cavity 2 and fuse and relay block 1, C5 cavity 3. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 23 | -- |
16 | Using a test lamp, check junction block 1, C4 cavity 1 to ground. Does the test lamp illuminate? | Go to Step 18 | Go to Step 19 |
17 | Replace the turn/hazard flasher on junction block 1. Is the repair complete? | Go to Step 23 | -- |
18 | Using a test lamp, check the hazard switch cavity 4 to ground. Does the test lamp illuminate? | Go to Step 13 | Go to Step 20 |
19 | Using a test lamp, check the junction block 1, C6 cavity 5 to ground. Does the test lamp illuminate? | Go to Step 21 | Go to Step 22 |
20 | Repair the open in the GRN/WHT wire between the hazard switch cavity 4 and the junction block 1, C4 cavity 1. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 23 | -- |
21 | Replace the junction block 1. Is the repair complete? | Go to Step 23 | -- |
22 | Repair the open in the GRN/WHT wire between the junction block 1 turn/hazard flasher cavity 3 and the junction block 1, C4 cavity 1. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 23 | -- |
23 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |