Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you review the Lighting System Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the dome lamps are inoperative. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Using a test lamp check the dome lamp connector from cavity 2 to ground. Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 | Replace the dome lamp assembly. Refer to Dome Lamp Replacement . Is the repair complete? | Go to Step 8 | -- |
5 | Inspect for an open in the dome lamp supply voltage circuit between the junction block and the dome lamp. Is an open condition present? | Go to Step 6 | Go to Step 7 |
6 | Replace the junction block. Is the repair complete? | Go to Step 8 | -- |
7 | Repair the open in the dome lamp supply voltage circuit between the junction block and the dome lamp. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |