Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Power Window Schematics | |||
1 | Did you review the Power Door Locks Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Doors |
2 |
Do the windows operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Are the Power Locks working properly? | Go to Step 4 | Go to Step 7 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the LH window/door lock switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
6 | Repair the voltage supply circuit of the LH window/door lock switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 9 | -- |
7 | Repair the open in the ground circuit of the LH window/door lock switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 9 | -- |
8 | Replace the LH window/door lock switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | Go to Step 9 | -- |
9 | Operate the system to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |