The combination valve has three sections. Each section
serves a different function.
• | The metering, or hold off, section limits front disc brake pressure,
allowing just enough pressure to overcome the rear brake shoe springs. When
the inlet pressure is below 200 kPa (30 psi), there is no
restriction. This allows for pressure equalization when the brakes are
not applied. |
• | The pressure differential warning switch constantly compares front
and rear brake pressures from the master cylinder. The switch activates the
BRAKE warning lamp when a malfunction occurs in the front or rear brake
system. The switch latches in the warning position after a malfunction
occurs. To turn off the lamp, you must repair the malfunction and apply
enough pedal pressure in order to develop about 3100 kPa (450 psi)
brake line pressure. |
• | The proportioning section limits brake line pressure to the rear
brakes after a predetermined rear input brake line pressure is reached. This
minimizes rear wheel lockup on vehicles with light rear wheel loads. |
The bypass feature on the combination valve ensures full system pressure
to the rear brakes when there is a malfunction in the front brake system.