Important: Do not bend the water outlet adapter pipe out of the way in order to remove the valve rocker arm cover.
13.1. | Loosen the bolt at the rear of the cylinder head. |
13.2. | Remove the 2 bolts that secure the bracket to the valve rocker arm cover. |
13.3. | Slide the bracket off of the bolt at the rear of the cylinder head. |
Important: The valve rocker arm cover gasket is reusable. Only replace the valve rocker arm cover gasket if it is damaged.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the rocker arm cover bolts to 10 N·m (89 lb in).
Tighten
Tighten the air cleaner outlet resonator bracket bolts to 10 N·m (89 lb in).
6.1. | Slide the bracket over the bolt at the rear of the cylinder head. |
6.2. | Install the 2 bolts that secure the bracket to the valve rocker arm cover. |
Tighten
Tighten