• | J 8092 Universal Driver Handle |
• | J 36660-A Electronic Torque Angle Meter |
• | J 36996 Balance Shaft Installer |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the balance shaft retainer bolts to 12 N·m (106 lb in).
6.1. | Use a wrench to secure the balance shaft. |
Place the wrench onto the balance shaft near to the balance shaft front bearing.
6.2. | Install the balance shaft driven gear bolt. |
Tighten
6.3. | Remove the wrench from the balance shaft. |