11.1. | Loosen the bolt at the rear of the cylinder head. |
11.2. | Remove the two bolts that secure the bracket to the valve rocker arm cover. |
11.3. | Slide the bracket off of the bolt at the rear of the cylinder head. |
• | Air cleaner outlet resonator bracket |
• | Fuel injector electrical connector bracket |
Important: The valve rocker arm cover gasket is reusable. Only replace the valve rocker arm cover gasket if it is damaged.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the stud and bolts to 10 N·m (89 lb in).
Tighten
Tighten the heater hose pipe bolt and the air cleaner outlet resonator
bracket bolts to 25 N·m (18 lb ft).
10.1. | Slide the bracket over the bolt at the rear of the cylinder head. |
10.2. | Install the two bolts that secure the bracket to the valve rocker arm cover. |
Tighten
Tighten
• | Tighten the EGR valve pipe to the EGR valve adapter bolts to 25 N·m (18 lb ft). |
• | Tighten the EGR valve pipe to intake manifold bolts to 10 N·m (89 lb in). |