The number(s) below refer to the step number(s) on the diagnostic table.
Listen for an audible click or feel for the click when the vacuum control assembly operates. Repeat the test as necessary.
Tests for voltage at the vacuum control assembly.
Verifies that the HVAC control module is providing ground to the vacuum control assembly.
Tests if ground is constantly being applied to the vacuum control assembly.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Air recirculation is inoperative or is always ON. | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the recirculation door move from the recirculation to the outside air position? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
Does the recirculation mode valve solenoid turn ON and OFF? | -- | Go to Step 4 | ||
Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 11 | |
Does the measured voltage change between the specified values? | 0-12 V | Go to Step 9 | Go to Step 6 | |
Does the measured voltage remain near the specified value? | 12 V | Go to Step 8 | Go to Step 7 | |
7 | Test the recirculation mode valve solenoid control circuit of the vacuum control assembly for a short to voltage or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 |
8 | Test the recirculation mode valve solenoid control circuit of the vacuum control assembly for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 |
9 | Inspect for poor connections at the vacuum control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 |
10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 |
11 | Repair the ignition 3 voltage circuit of the vacuum control assembly. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 14 | -- |
12 | Replace the vacuum control assembly. Refer to Vacuum Control Assembly Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- |
13 |
Important: Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |