Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate in any speed position? | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 11 |
4 |
Does the test lamp illuminate? | Go to Step 12 | Go to Step 5 |
5 | Test the high blower motor control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 6 |
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 10 |
7 | Connect a test lamp between the battery positive voltage circuit of the HVAC control module and a good ground. Does the test lamp illuminate? | Go to Step 8 | Go to Step 9 |
8 | Test the ground circuits of the HVAC control module for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
9 | Repair the battery positive voltage circuit of the HVAC control module. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 16 | -- |
10 | Repair the ignition 3 voltage circuit of the HVAC control module. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 16 | -- |
11 | Repair the blower motor supply voltage circuit of the blower motor. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 16 | -- |
12 | Inspect for poor connections at the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
13 | Inspect for poor connections at the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
14 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |