The numbers below refer to the step numbers on the diagnostic table.
To observe the recirculation door actuator, lower the glove box door off of the upper attachments.
This step tests the HVAC control module's ability to reverse the polarity of the door control A and door control B circuits. The test lamp should illuminate.
Step | Action | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | |||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |||||||||||||
Does the recirculation door move from the recirculation to the outside air position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | |||||||||||||
3 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 4 | ||||||||||||
4 | Connect a test lamp between the recirculation door control B circuit of the recirculation actuator and a good ground. Does the test lamp illuminate? | Go to Step 7 | Go to Step 8 | ||||||||||||
Place the recirculation switch in the OFF position. Does the test light illuminate? | Go to Step 6 | Go to Step 10 | |||||||||||||
6 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | Go to Step 13 | Go to Step 9 | ||||||||||||
7 | Test the recirculation door control A circuit of the HVAC control module for a short to ground, short to voltage, an open and for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 10 | ||||||||||||
8 | Test the recirculation door control B circuit of the HVAC control module for a short to ground, short to voltage, an open and for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 10 | ||||||||||||
9 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 | ||||||||||||
10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 | ||||||||||||
11 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | Go to Step 13 | -- | ||||||||||||
12 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 13 | -- | ||||||||||||
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |