Subject: | Instrument Panel Air Outlets Binding or Broken (Install Washers on Instrument Panel Air Outlet Attaching Studs) |
Models: | 2003-2005 Chevrolet SSR |
Some customers may comment on a binding or broken instrument panel (IP) air outlet.
This condition may be caused by a lack of clearance between the IP and the IP air outlet.
Technicians are to install a single washer on each of the attaching studs between the IP and the IP air outlet. This will provide more clearance between the two parts to prevent the binding condition. Use the following procedure to install the washers on the IP air outlet(s) that are binding:
The washers listed below are packaged in quantities of 10. The two outer air outlets will use two washers each. The two inner air outlets will use three washers each.
Part Number | Description | Qty |
---|---|---|
15650962 | Washer-Flat (Hardened) (M8, 8x18x2.3, SPST) | As Required |
Parts are currently available from GMSPO.
For vehicles repaired under warranty, use:
Labor Operation | Description | Labor Time |
---|---|---|
D1440 | Deflector, Air (Outlet Vent)-Right - Replace | Use Published Labor Operation Time |
D1441 | Deflector, Air (Outlet Vent)-Left - Replace | Use Published Labor Operation Time |
D1442 | Deflector, Air (Outlet Vent)-Right Center - Replace | Use Published Labor Operation Time |
D1443 | Deflector, Air (Outlet Vent)-Left Center - Replace | Use Published Labor Operation Time |