GM Service Manual Online
For 1990-2009 cars only

Instrument Panel Air Outlets Binding or Broken (Install Washers on Instrument Panel Air Outlet Attaching Studs)

Subject:Instrument Panel Air Outlets Binding or Broken (Install Washers on Instrument Panel Air Outlet Attaching Studs)

Models:2003-2005 Chevrolet SSR



Condition

Some customers may comment on a binding or broken instrument panel (IP) air outlet.

Cause

This condition may be caused by a lack of clearance between the IP and the IP air outlet.

Correction

Technicians are to install a single washer on each of the attaching studs between the IP and the IP air outlet. This will provide more clearance between the two parts to prevent the binding condition. Use the following procedure to install the washers on the IP air outlet(s) that are binding:

  1. Remove the center trim panel from the IP. Refer to the Trim Panel Replacement-Instrument Panel (IP) Center procedure in SI (Document ID #1385566).
  2. Remove the IP air outlet(s) that are binding. Refer to the Air Outlet Replacement-Instrument Panel procedure in SI (Document ID #1385671).
  3. Install a single washer, P/N 15650962, on each IP air outlet attaching stud. Two or three washers will be required depending on which IP air outlet is being worked on.
  4. Install the IP air outlet(s) onto the center trim panel. Refer to the Air Outlet Replacement-Instrument Panel procedure in SI (Document ID #1385671).
  5. Install the center trim panel. Refer to the Trim Panel Replacement-Instrument Panel (I/P) Center procedure in SI (Document ID #1385566).

Parts Information

The washers listed below are packaged in quantities of 10. The two outer air outlets will use two washers each. The two inner air outlets will use three washers each.

Part Number

Description

Qty

15650962

Washer-Flat (Hardened) (M8, 8x18x2.3, SPST)

As Required

Parts are currently available from GMSPO.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Description

Labor Time

D1440

Deflector, Air (Outlet Vent)-Right - Replace

Use Published Labor Operation Time

D1441

Deflector, Air (Outlet Vent)-Left - Replace

Use Published Labor Operation Time

D1442

Deflector, Air (Outlet Vent)-Right Center - Replace

Use Published Labor Operation Time

D1443

Deflector, Air (Outlet Vent)-Left Center - Replace

Use Published Labor Operation Time