The roof door module (RDM) checks the folding top outer latch position switch released signal circuit at least once every 200 milliseconds.
The folding top outer latch position switch is supplied with a constant ground source.
When the switch is active, the RDM will detect a switched ground signal on the folding top outer latch position switch released signal circuit indicating that the latch is released.
• | The battery voltage is between 9-16 volts. |
• | The ignition is in the Run or Accessory position or retained accessory power (RAP) is active. |
• | A request for folding top open operation has been received by the RDM, and the RDM attempts to open the folding top. |
If the RDM detects inputs from either the folding top outer latch position switch latched or folding top outer latch position switch released signal circuits out of sequence during the folding top operation.
• | Stores a current and history DTC B1300 in the RDM. |
• | Folding top operation is suspended. |
• | This DTC will clear on the current status after the condition for setting the fault is corrected. |
• | A history DTC will clear after 50 consecutive ignition cycles without a fault present. |
• | History and current DTC can be cleared using the scan tool. |
If the DTC does not reset after the code is cleared, then the switch may be the source of an intermittent fault. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
Schematic Reference: Folding Top Schematics Connector End View Reference: Power and Grounding Connector End Views in Wiring Systems | |||||||
1 | Did you perform the Power Roof Diagnostic System Check? | Go to Step 2 | |||||
2 |
When the roof is completely closed, the Header Latch Switch parameter will display Latched. When the roof is completely open, the Header Latch Switch will display Unlatched. Does the scan tool display the appropriate switch state? | Go to Step 3 | Go to Step 4 | ||||
3 |
Does the Header Latch Switch parameter change state? | Go to Diagnostic Aids | Go to Step 4 | ||||
4 |
Does the scan tool display Transition? | Go to Step 7 | Go to Step 5 | ||||
5 | Test for one of the following conditions. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems.
Did you find and correct the condition? | Go to Step 10 | Go to Step 6 | ||||
6 | Inspect for poor connections at the harness connector of the RDM. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 8 | ||||
7 | Inspect for poor connections at the harness connector of the folding top outer latch position switch. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 | ||||
8 |
Important: Always perform the reinitialization of the power windows procedure for the RDM.
Did you complete the replacement? | Go to Step 10 | -- | ||||
9 | Replace the folding top outer latch position switch. Refer to Folding Top Latch Replacement - Center . Did you complete the replacement? | Go to Step 10 | -- | ||||
10 |
Does the DTC reset? | Go to Step 2 | System OK |