The roof door module (RDM) monitors the folding top outer latch striker position switch at least once every 200 milliseconds. The folding top outer latch striker position switch is a three position switch that the RDM uses to determine roof position in relation to the header. The switch is tripped by the dowel pin on the folding top front panel as the top approaches the header. The switch tells the RDM that the roof is aligned and the latching process can begin.
• | The battery voltage is between 9-16 volts. |
• | Ignition is in the Accessory or Run position or retained accessory power (RAP) is active. |
• | A request for folding top operation has been received by the RDM, and the RDM attempts to operate the folding top. |
• | If the RDM detects an open or short to voltage in the folding top outer latch striker over center signal circuit , the DTC will set. |
• | If the RDM detects an open in the ground circuit of the folding top outer latch striker position switch, the DTC will set. |
• | If the RDM detects that the dowel pin is engaged and the RDM commands the roof down for approximately 30 seconds and the folding top cylinder position sensor is active, the DTC will set. |
• | If the RDM commands the roof up for approximately 30 seconds and the dowel pin is not engaged and the folding top cylinder position sensor is active, the DTC will set. |
• | Stores a current DTC B3683 in the RDM. |
• | Folding top operation is suspended. |
• | This DTC will clear on the current status after the condition for setting the fault is corrected. |
• | A history DTC will clear after 50 consecutive ignition cycles without a fault present. |
• | History and current DTC can be cleared using the scan tool. |
If the DTC does not reset after the code is cleared, then the switch may be the source of an intermittent fault. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
Schematic Reference: Folding Top Schematics Connector End View Reference: Power Roof Systems Connector End Views | |||||||
1 | Did you perform the Power Roof Diagnostic System Check? | Go to Step 2 | |||||
2 |
With the roof stowed, the Roof Dowel Pin Switch should display Disengaged. With the roof closed, the Roof Dowel Pin Switch should display Engaged. Does the scan tool display the appropriate state? | Go to Step 3 | Go to Step 4 | ||||
3 |
Does the Roof Dowel Pin Switch parameter change state? | Go to Diagnostic Aids | Go to Step 4 | ||||
4 |
Does the scan tool display Transition or Engaged? | Go to Step 5 | Go to Step 6 | ||||
5 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 10 | ||||
6 |
Does the scan tool display Over Center or Disengaged or does the jumper fuse open? | Go to Step 9 | Go to Step 7 | ||||
7 | Test for an open, high resistance, short to ground, or short to voltage in the folding top outer latch striker over center signal circuit. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 8 | ||||
8 | Inspect for poor connections at the harness connector of the RDM. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 | ||||
9 | Inspect for the following:
Did you find and correct the condition? | Go to Step 13 | Go to Step 12 | ||||
10 | Repair the open in the folding top outer latch striker position switch ground circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- | ||||
11 |
Important: Always perform the reinitialization of the power windows procedure for the RDM.
Did you complete the replacement? | Go to Step 13 | -- | ||||
12 | Replace the folding top outer latch striker position switch. Refer to Folding Top Latch Replacement - Side . Did you complete the replacement? | Go to Step 13 | -- | ||||
13 |
Does the DTC reset? | Go to Step 2 | System OK |