Removal Procedure
Important: Clean the tube connections and surrounding
areas before disconnecting in order to avoid possible evaporative emission (EVAP)
system contamination.
- Disconnect the EVAP tube from the EVAP canister purge
solenoid.
• | Push the large size white retainer portion in. |
• | Push down, while pulling up slightly in order to disengage the tube. |
- Disconnect the EVAP tube from the chassis EVAP pipe.
• | Push the large size white retainer portion in. |
• | Push down, while pulling up slightly in order the disengage the tube. |
- Remove the EVAP tube.
- Cap the EVAP canister purge solenoid and the EVAP chassis pipe in order
to prevent possible EVAP system contamination.
Installation Procedure
- Remove the caps from the EVAP canister purge solenoid
and the EVAP chassis pipe.
- Install the EVAP tube.
- Connect the EVAP tube to the EVAP chassis pipe.
- Connect the EVAP tube to the EVAP canister purge solenoid.