3.1. | Remove the clip from around the engine harness and the oxygen sensor pigtail. |
3.2. | Disconnect the connector position assurance (CPA) retainer. |
3.3. | Disconnect the forward oxygen sensor electrical connector. |
4.1. | Unclip the oxygen sensor electrical connector from the hose clip. |
4.2. | Disconnect the CPA retainer. |
4.3. | Disconnect the oxygen sensor electrical connector (1). |
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the nuts to 50 N·m (37 lb ft).
6.1. | Connect the oxygen sensor electrical connector (1). |
6.2. | Connect the CPA retainer. |
6.3. | Clip the oxygen sensor electrical connector to the hose clip. |
7.1. | Connect the forward oxygen sensor electrical connector. |
7.2. | Connect the CPA retainer. |
7.3. | Install the clip around the engine harness and the oxygen sensor pigtail. |