Removal Procedure
- Using a trim tool, pry up in order to release the
gauge assembly (1) clips from the bracket.
- Disconnect the electrical connector.
- Remove nut (1) securing the gauge bracket.
- Remove the nut securing the gauge bracket to the I/P assembly.
Installation Procedure
- Locate the bracket to the I/P.
Notice: Refer to Fastener Notice in the Preface section.
- Attach the fastener to the I/P support.
Tighten
Tighten the fastener to 25 N·m (18 lb ft).
- Install the nut (1) to the bracket.
Tighten
Tighten the nut to 10 N·m (88 lb in).
- Connect the electrical connector.
- Install the gauge assembly (1) to the bracket.